Rascom QAF-1R at 2.9°E-Norh Africa : 11 430 MHz_H BIS-AFRICA
SK_Uskutočnil som prvý signálny monitoring frekvencie f=11 430 MHz-H na výstupe z PF Prodelin 370 cm v stredoeurópskej zóne s dosiahnutou stabilitou príjmu 99,41%,so špičkou kvality SNR=9,4 dB,CN=13,0 dB...
EN_Rascom QAF-1R at 2.9°E_NORTH Africa : I conducted the first signal monitoring of the frequency f = 11,430 MHz_H at the output of a Prodelin 370 cm reflector in the Central European zone, achieving a reception stability of 99.41 %, with a peak quality of SNR = 9.4 dB and CN = 13.0 dB.
DE_Ich führte das erste Signal-Monitoring der Frequenz f = 11,430 MHz_H am Ausgang eines Prodelin-Reflektors mit 370 cm in der mitteleuropäischen Zone durch und erzielte eine Empfangsstabilität von 99,41 %, mit einer Spitzenqualität von SNR = 9,4 dB und CN = 13,0 dB.
Teoretický Úvod do problematiky príjmu v zónach "Out of footprint" a následná analýza dosiahnutého stavu v signálnom monitoringu ...
1. Fyzikálny princíp prijímania signálu v zóne Out Of Footprint (OOF)
V zónach mimo oficiálny footprint (OOF) dochádza k výraznému poklesu hustoty výkonu elektromagnetickej vlny, pretože anténny systém satelitu vysiela lúč s definovaným ziskom a šírkou vyžarovacieho diagramu (3 dB lúč, half-power beamwidth). Na okrajoch a mimo oficiálny EIRP diagram je signál prijímaný často,alebo len z vedľajších lalokov vyžarovacieho diagramu, kde už amplitúdová charakteristika lúča prudko klesá — obvykle o 10 až 20 dB na každých 2–3° od stredu hlavného lúča.
Z pohľadu vlnovej fyziky ide o šírenie elektromagnetického poľa v priestore s čiastočnou stratou koherencie fázy, pretože vlna prichádzajúca z OOF zóny má rozpadnutý fázový front a vysoký stupeň deformácie polarizačného vektora.
Preto sa v zónach OOF objavuje jav fázovej nestability (phase jitter) a mikromodulácií amplitúdy spôsobených interferenciou viacnásobných odrazov signálu v troposfére, čo z fyzikálneho hľadiska vedie k neustálej oscilácii úrovne SNR v krátkych časových intervaloch (1–10 s).
2. Elektromagnetická vlna a koherencia v prijímacej rovine
Pri príjme mimo oficiálne pokrytie je rozhodujúca fázová koherencia elektromagnetickej vlny na ploche reflektora. Ak je vlnová dĺžka λ = 2,63 cm (pre f = 11,430 GHz) a efektívny priemer reflektora D = 370 cm, potom sa v prijímacej rovine vytvára interferenčný obrazec s približne 140 koherentnými periódami vlny. Pri nestabilných podmienkach (napr. kolísanie refrakčného indexu troposféry v dôsledku dažďa alebo vlhkosti) dochádza ku kolísaniu fázy jednotlivých častí prijatej vlny, čo spôsobuje časovo premennú deformáciu fázového čela.
Aj napriek tomu možno dosiahnuť stabilitu Locku nad 99 %, ak je reflektor dostatočne veľký na zachytenie aj čiastočne nekoherentnej časti poľa — teda ak zberná plocha antény presiahne tzv. hranicu kritického apertúrneho pomeru, ktorý pre Ku pásmo dosahuje hodnotu približne D > 3λ√(Gsat/Gearth).
Pre družicu Rascom QAF-1R a frekvenciu 11,430 GHz je to približne Dkrit = 2,7 m, čo znamená, že môj reflektor D = 3,7 m túto hranicu prekračuje o viac ako 35 %, a tým zabezpečuje čiastočnú rekonštrukciu fázového frontu v prijímacej rovine.
3. Úloha dažďových prehánok a fyzikálny útlm...Pri bežných stredoeurópskych prehánkach s R = 8–10 mm/h dochádza k útlmu približne 0,4–0,6 dB/km, čo pri vertikálnej dráhe 3–4 km predstavuje celkový útlm signálu 1,5–2,5 dB. Môj meraný priebeh s poklesom SNR z 9,4 dB na 5,2 dB počas najintenzívnejšieho dažďa presne korešponduje s týmto fyzikálnym modelom. (vysvetlivky : R je intenzita dažďa v mm/h,k a α sú empirické koeficienty pre Ku pásmo (napr. k = 0,0308, α = 1,131)
4.Fyzikálne potvrdenie stability v režime Lock : Stabilita Locku mimo oficiálneho footprintu je determinovaná časovo-priestorovou koherenciou prijímaného poľa, ktorú možno v mojom prípade kvantifikovať ako:
Tento koeficient koherencie Locku (Ct) = 0,9941 znamená, že fázová a amplitúdová stabilita v mojom meraní presahuje 99 %, čo v rámci vlnovej fyziky zodpovedá koherentnému prijímu 2. rádu (druhého stupňa), t. j. systému, kde dochádza k fázovému viazaniu signálu počas celej periódy sledovania.
5,Záver teoretického úvodu : Na základe experimentu možno vedecky potvrdiť, že aj v zónach OOF, kde úroveň EIRP klesá pod oficiálne hranice (napr. < 38 dBW), je možné dosiahnuť stabilný a dlhodobo udržateľný Lock s reflektorom D ≥ 3,7 m, a to aj bez fázovej korekcie pomocou syntetických metód, ak je prijímací systém optimalizovaný z hľadiska impedančnej prispôsobenosti,nízkeho šumu LNB a presnej polarizačnej uhlovej korekcie,alebo odchýlky vlnenia-SKEW.
>Analýza dosiahnutého stavu v signálnom monitoringu :
Ešte predtým, ako uskutočním dokazovanie o stabilite príjmu z frekvencie f = 11 430 MHz_H, koncentrovanej do severného diagramu družice Rascom QAF-1R na 2,9°E, na výstupe z PF 450 cm s dostatočnou verifikačnou alebo dôkaznou váhou jednotky signálneho monitoringu t = 72 hodín, Vám dnes dokážem, že aj na výstupe z reflektora s priemerom D = 370 cm je možné v stredoeurópskej praxi príjmu dosiahnuť stabilitu príjmu vyššiu ako 99 %, a to aj napriek celodennému výskytu dažďových prehánok v mieste príjmu — v meste Lučenec.
Dnes vykonám detailnú analýzu dosiahnutého priebehu signálneho monitoringu frekvencie f = 11 430 MHz_H na výstupe z PF 370 cm v nedôkaznej, ale pre tento účel postačujúcej jednotke monitoringu t = 24 hodín, aby som tým pomenoval a zároveň analyzoval dosiahnutú stabilitu príjmu a špičku kvality pri aplikácii bežného prírubového UNI/DRO LNB značky Invacom SNF-031, vyrobeného v roku 2006. To len potvrdzuje, že aj s bežnými komponentmi signálneho reťazca, a to bez nutnosti aplikácie môjho technologického vynálezu s názvom „Synchrónne nanokorekcie“, je možné v zemepisnej oblasti strednej Európy dosiahnuť pri aktuálnej intenzite výkonu EIRP stabilitu príjmu vyššiu ako 99 % aj na výstupe z reflektora PF 370 cm z analyzovanej frekvencie f = 11 430 MHz_H.
Dnes, 12. 11. 2025 o 11:00 CET, je obsadenie transportného streamu identické, alebo rovnaké so stavom zo dňa 9. 11. 2025, keď som vykonával zber nameraných údajov z frekvenčného spektra pomocou nového referenčného analyzátora spektra a kvality na dxsatcs.com, ktorým je Televes Mosaiq-6 s opciou 4K-UHD. To znamená, že dnes publikované dáta o stave v transportnom streame alebo v PAT mriežke na frekvencii f = 11 430 MHz_H sú tie najaktuálnejšie vôbec.
Analýza signálneho monitoringu frekvencie f = 11 430 MHz_H na výstupe z PF 370 cm:
V dňoch od 8. 11. do 9. 11. 2025 som v nedôkaznej jednotke t = 25 hodín a 33 minút uskutočnil výkon jedného kontinuálneho signálneho monitoringu frekvencie 11 430 MHz_H na výstupe z reflektora Prodelin s D = 370 cm v mieste príjmu Lučenec, pri celkovo výrazne zhoršených poveternostných podmienkach pravidelného výskytu dažďových prehánok, čo samozrejme dokazuje diagram výsledkov úhrnu dažďových zrážok zo zdroja shmu.sk / Boľkovce.
Z celkovej dĺžky signálneho monitoringu jednotky t = 1533 minút, čo predstavuje 25 hodín a 33 minút, som dosiahol plne stabilný príjem na 100 % bez jedinej pixelácie v obraze alebo zamrznutia streamu v dĺžke presne 1524 minút, čo v percentuálnom vyjadrení znamená, že som
dosiahol stabilitu príjmu 99,41 % na výstupe z PF 370 cm, a to aj pri takmer celodennom výskyte dažďových prehánok od 8. do 9. 11. 2025.
Pravidelný výskyt špičky kvality okolo SNR = 9,4 dB zaznamenávam každý deň od 13:00 do 20:00 večer, čo len dokazuje, že moje tvrdenia o možnosti aplikačného použitia priemeru reflektora od D = 300 cm pre možnosť nestabilného locku nosnej v dĺžke jednotiek hodín denne na f = 11 430 MHz_H v strednej Európe majú svoj racionálny základ. Špička kvality pri dosiahnutej SNR = 9,4 dB znamená, že môj signálny reťazec s D = 370 cm generuje výšku signálovej rezervy až 4,2 dB, čo samozrejme dáva priestor pre pokusy v smere dosiahnutia nestabilnej formy locku už na výstupe z PF 300 cm.
Na prelome dní, okolo polnoci medzi 8. a 9. 11. 2025, som zaznamenal po príchode mohutnej dažďovej oblačnosti totálny výpadok v kontinuite locku nosnej v dĺžke presne 9 minút, a zároveň to bol jediný trvalý, resp. kontinuálne prezentovaný a zaznamenaný výpadok locku z celkovej dĺžky monitoringu 1533 minút na tejto monitorovanej nosnej, ktorého výskyt je v priamej príčinnej súvislosti s výskytom dažďových prehánok v mieste príjmu, tak ako to nespochybniteľne dokazujú diagramy úhrnu zrážok zo zdroja shmu.sk / stanica Boľkovce.
Obsadenie transportného streamu na f = 11 430 MHz_H:
Prevádzkovateľ Rascom ešte pred začiatkom posledného víkendu doplnil transportný stream na nosnej frekvencii f = 11 430 MHz_H o TV Canal 2 International v plnom HD rozlíšení 1920×1080 a o spravodajskú TV France 24 (Fr) v SD rozlíšení 720×576, takže aktuálne už TS obsahuje dva TV prenosy v plnom HDTV rozlíšení, jeden v SD rozlíšení a jeden rádiový prenos Radio Kalangou. To je stav ku dnešnému dňu 12. 11. 2025 o 11:00 hod.
Theoretical Introduction to the Issue of Reception in “Out-of-Footprint” Zones and Subsequent Analysis of the Achieved State in Signal Monitoring …
1. Physical Principle of Signal Reception in the Out-of-Footprint (OOF) Zone
In zones outside the official footprint (OOF), a significant decrease in the power density of the electromagnetic wave occurs because the satellite’s antenna system transmits a beam with a defined gain and beamwidth (3 dB beam, half-power beamwidth). At the edges and beyond the official EIRP diagram, the signal is often—or only—received from the side-lobes of the radiation pattern, where the amplitude characteristic of the beam falls sharply—typically by 10 to 20 dB for every 2–3° from the centre of the main beam. From the viewpoint of wave physics, this corresponds to the propagation of an electromagnetic field in space with partial loss of phase coherence, because the wave arriving from the OOF zone has a degraded phase-front and a high degree of deformation of the polarization vector. Therefore, phenomena of phase instability (phase jitter) and micro-amplitude modulations caused by interference of multiple signal reflections in the troposphere occur in OOF zones—which from a physical perspective leads to continuous oscillation of the SNR level in short time-intervals (1–10 s).
2. Electromagnetic Wave and Coherence in the Receiving Plane For reception outside the official coverage, the decisive factor is the phase coherence of the electromagnetic wave across the reflector aperture. If the wavelength is λ = 2.63 cm (for f = 11.430 GHz) and the effective diameter of the reflector D = 370 cm, then an interference pattern with approximately 140 coherent wave-periods is formed in the receiving plane. Under unstable conditions (e.g., fluctuations of the troposphere’s refractive index due to rain or humidity) phase variations of individual parts of the received wave occur, causing time-variable deformation of the phase front.
Nevertheless, it is possible to achieve lock-stability above 99 % if the reflector is sufficiently large to capture even the partially incoherent portion of the field—i.e., if the collecting aperture exceeds the so-called critical aperture ratio, which for the Ku-band is approximately D > 3 λ√(G_sat/G_earth).
For the satellite Rascom QAF-1R and the frequency 11.430 GHz this is approximately D_crit = 2.7 m, which means that my reflector D = 3.7 m surpasses this threshold by more than 35 %, thereby ensuring partial reconstruction of the phase front in the receiving plane.
3. Role of Rain Showers and Physical Attenuation
In typical Central European rain showers with R = 8–10 mm/h, attenuation of approximately 0.4–0.6 dB/km occurs, which for a vertical path of 3–4 km corresponds to a total signal attenuation of 1.5–2.5 dB. My measured course with a drop of SNR from 9.4 dB to 5.2 dB during the most intense rain corresponds exactly to this physical model. (Explanations: R is rain-rate in mm/h; k and α are empirical coefficients for the Ku-band (for example k = 0.0308, α = 1.131)).
4. Physical Confirmation of Stability in the Lock-Mode
The stability of carrier-lock outside the official footprint is determined by the time-space coherence of the received field, which in my case can be quantified as:

This coherence coefficient (C_t = 0.9941) means that the phase- and amplitude-stability in my measurement exceeds 99 %, which within wave-physics corresponds to a second-order coherent reception system, i.e., a system in which phase-locking of the signal occurs for the entire observation period.
5. Conclusion of Theoretical Introduction
Based on the experiment, it can be scientifically confirmed that even in OOF zones, where the EIRP level falls below the official boundary (e.g., < 38 dBW), it is possible to achieve a stable and long-term sustainable lock with a reflector D ≥ 3.7 m, and that even without phase-correction by synthetic methods — provided the receiving system is optimised in terms of impedance matching, low LNB noise, and precise polarisation-angular correction or skew compensation.
Analysis of the Achieved State in Signal Monitoring:
Before I proceed with the verification of reception stability from frequency f = 11.430 MHz_H, concentrated into the northern radiation diagram of the Rascom QAF-1R satellite at 2.9°E, at the output of PF 450 cm with sufficient verification or evidential weight of the signal-monitoring unit t = 72 hours, I will show you today that even at the output from a reflector with diameter D = 370 cm one can in Central-European practice of reception achieve a reception stability higher than 99 %—even despite all-day occurrence of rain showers at the reception site—the city of Lučenec.
Today I carry out a detailed analysis of the achieved course of signal-monitoring of frequency f = 11.430 MHz_H at the output of PF 370 cm in a non-evidential but for this purpose sufficient monitoring unit t = 24 hours, in order to designate and simultaneously analyse the achieved reception stability and quality peak when applying a standard flange-mounted UNI/DRO LNB of the Invacom SNF-031 brand manufactured in 2006. This confirms that even with standard components of the signal chain, and without the necessity of applying my technological invention named “Synchronous Nanocorrections”, it is possible in the geographic area of Central Europe, at the current EIRP intensity, to achieve reception stability higher than 99 % even at the output of the PF 370 cm reflector from the analysed frequency f = 11.430 MHz_H.
Today, 12 Nov 2025 at 11:00 CET, the transport-stream occupancy is identical or equivalent to the state as of 9 Nov 2025, when I collected measured data from the frequency spectrum using the new reference analyser Televes Mosaiq-6 with 4K-UHD option at dxsatcs.com. This means that today published data about the state of the transport stream or PAT-network on frequency f = 11.430 MHz_H are the most up-to-date available.
Signal Monitoring Analysis of Frequency f = 11.430 MHz_H at the output of PF 370 cm:
Between 8 Nov and 9 Nov 2025, in a non-evidential monitoring unit t = 25 hours 33 minutes I conducted one continuous signal monitoring of frequency 11.430 MHz_H at the output of a Prodelin reflector with D = 370 cm in the reception location Lučenec, under overall significantly deteriorated meteorological conditions of frequent rain-showers, as proved by the precipitation-sum diagrams from the source shmu.sk / Bolkovce.
From the total duration of the signal monitoring unit t = 1533 minutes (which represents 25h 33m) I achieved a fully stable reception at 100 % with no single pixelation in the image or stream-freeze for exactly 1524 minutes, which in percentage expression means that I achieved a reception stability of 99.41 % at the output of PF 370 cm—even in the face of almost whole-day occurrence of rain-showers from 08 to 09 Nov 2025.
A regular occurrence of a quality peak around SNR = 9.4 dB I record every day from 13:00 to 20:00 evening, which only demonstrates that my claims about the possibility of applicational usage of reflectors from D = 300 cm for the possibility of an unstable carrier-lock lasting units of hours daily on f = 11.430 MHz_H in Central Europe have their rational basis. The quality-peak at achieved SNR = 9.4 dB means that my signal-chain with D = 370 cm generates a signal-margin of up to 4.2 dB, which naturally provides room for experiments towards achieving an unstable form of lock already at the output of PF 300 cm.
Around the midnight between 8 and 9 Nov 2025, immediately after the arrival of heavy rain-clouds I registered a total interruption of carrier-lock continuity for exactly 9 minutes—and at the same time it was the only persistent or continuously presented and documented lock-out of the entire monitoring length of 1533 minutes on this monitored carrier, whose occurrence is in direct causal relation to the rainfall-showers at the reception site, as the precipitation-sum diagrams from the source shmu.sk / station Bolkovce prove incontrovertibly.
Transport Stream Occupancy on f = 11.430 MHz_H:
The operator Rascom, just before the last weekend, supplemented the transport stream on the carrier frequency f = 11.430 MHz_H with TV Canal 2 International in full HD resolution 1920 × 1080 and with the news-channel France 24 (Fr) in SD resolution 720 × 576, so that currently the TS includes two TV transmissions in full HDTV resolution, one in SD resolution and one radio transmission Radio Kalangou. That is the state as of today 12 Nov 2025 at 11:00 CET.
Theoretische Einführung in die Problematik des Empfangs in „Out-of-Footprint“-Zonen und anschließende Analyse des erreichten Zustands im Signal-Monitoring
1. Physikalisches Prinzip des Signalempfangs in der Out-of-Footprint (OOF)-Zone
In Zonen außerhalb des offiziellen Footprints (OOF) kommt es zu einem signifikanten Abfall der Leistungsdichte der elektromagnetischen Welle, da das Antennensystem des Satelliten einen Strahl mit definiertem Gewinn und Strahlbreite (3 dB‑Beam, Halbwertsbreite) abstrahlt. Am Rand und außerhalb des offiziellen EIRP-Diagramms wird das Signal oft – oder nur – aus den Nebenkeulen des Strahlungsmusters empfangen, wo die Amplitudencharakteristik des Strahls stark abfällt – typischerweise um 10 bis 20 dB pro 2–3° vom Zentrum des Hauptstrahls. Aus der Sicht der Wellenphysik handelt es sich hierbei um die Ausbreitung eines elektromagnetischen Feldes im Raum mit teilweisem Verlust der Phasenkohärenz, da die aus der OOF-Zone eintreffende Welle eine gestörte Phasenfront und einen hohen Grad an Deformation des Polarisationsvektors aufweist. Daher treten in OOF-Zonen Phaseninstabilitäten (Phase Jitter) und Mikro-Amplitudenmodulationen auf, die durch Interferenzen multipler Signalreflexionen in der Troposphäre verursacht werden, was physikalisch zu kontinuierlichen Oszillationen des SNR-Niveaus in kurzen Zeitintervallen (1–10 s) führt.
2. Elektromagnetische Welle und Kohärenz in der Empfangsebene Für den Empfang außerhalb der offiziellen Abdeckung ist die Phasenkohärenz der elektromagnetischen Welle über die Fläche des Reflektors entscheidend. Bei einer Wellenlänge von λ = 2,63 cm (für f = 11,430 GHz) und einem effektiven Reflektordurchmesser D = 370 cm entsteht in der Empfangsebene ein Interferenzmuster mit etwa 140 kohärenten Wellenperioden. Unter instabilen Bedingungen (z. B. Schwankungen des Brechungsindex der Troposphäre durch Regen oder Feuchtigkeit) kommt es zu Phasenschwankungen einzelner Teile der empfangenen Welle, was eine zeitlich variable Deformation der Phasenfront verursacht. Nichtsdestotrotz kann eine Lock-Stabilität von über 99 % erreicht werden, wenn der Reflektor groß genug ist, um auch den teilweise inkohärenten Teil des Feldes zu erfassen – d. h., wenn die Sammelfläche der Antenne das sogenannte kritische Aperturverhältnis überschreitet, das für das Ku-Band ungefähr D > 3 λ√(G_sat/G_earth) beträgt. Für den Satelliten Rascom QAF‑1R und die Frequenz 11,430 GHz beträgt dies etwa D_crit = 2,7 m, was bedeutet, dass mein Reflektor D = 3,7 m diese Grenze um mehr als 35 % überschreitet und somit eine partielle Rekonstruktion der Phasenfront in der Empfangsebene gewährleistet.
3. Rolle von Regenschauern und physikalische Dämpfung
Bei typischen mitteleuropäischen Schauern mit R = 8–10 mm/h tritt eine Dämpfung von ca. 0,4–0,6 dB/km auf, was bei einer vertikalen Strecke von 3–4 km einer Gesamtdämpfung des Signals von 1,5–2,5 dB entspricht. Mein gemessener Verlauf mit einem SNR-Abfall von 9,4 dB auf 5,2 dB während des stärksten Regens entspricht exakt diesem physikalischen Modell. (Erläuterungen: R ist die Regenintensität in mm/h; k und α sind empirische Koeffizienten für das Ku-Band (z. B. k = 0,0308, α = 1,131)).
4. Physikalische Bestätigung der Stabilität im Lock-Modus
Die Stabilität des Carrier-Locks außerhalb des offiziellen Footprints wird durch die zeitlich-räumliche Kohärenz des empfangenen Feldes bestimmt, die in meinem Fall wie folgt quantifiziert werden kann:

Dieser Kohärenzkoeffizient (C_t = 0,9941) bedeutet, dass die Phasen- und Amplitudenstabilität in meiner Messung über 99 % liegt, was in der Wellenphysik einem kohärenten Empfang zweiter Ordnung entspricht, d. h. einem System, bei dem die Phasenbindung des Signals während der gesamten Beobachtungsperiode erfolgt.
5. Schlussfolgerung der theoretischen Einführung Basierend auf dem Experiment kann wissenschaftlich bestätigt werden, dass selbst in OOF-Zonen, in denen das EIRP-Niveau unter die offizielle Grenze fällt (z. B. < 38 dBW), ein stabiler und langfristig nachhaltiger Lock mit einem Reflektor D ≥ 3,7 m möglich ist – auch ohne Phasenkorrektur durch synthetische Methoden, sofern das Empfangssystem hinsichtlich Impedanzanpassung, niedrigem LNB-Rauschfaktor und präziser Polarisationswinkelkorrektur oder Skew-Kompensation optimiert ist.
Analyse des erreichten Zustands im Signal-Monitoring:
Bevor ich die Überprüfung der Empfangsstabilität von der Frequenz f = 11,430 MHz_H vornehme, konzentriert auf das nördliche Strahlungsmuster des Satelliten Rascom QAF‑1R bei 2,9°E, am Ausgang von PF 450 cm mit ausreichendem Verifikations- oder Evidenzgewicht der Signal-Monitoring-Einheit t = 72 Stunden, zeige ich heute, dass auch am Ausgang eines Reflektors mit Durchmesser D = 370 cm in der mitteleuropäischen Empfangspraxis eine Empfangsstabilität von über 99 % erreicht werden kann – selbst bei ganztägigem Regen am Empfangsort, der Stadt Lučenec.
Heute führe ich eine detaillierte Analyse des erzielten Verlaufs des Signal-Monitorings der Frequenz f = 11,430 MHz_H am Ausgang von PF 370 cm in einer nicht-evidenziellen, aber für diesen Zweck ausreichenden Monitoring-Einheit t = 24 Stunden durch, um die erreichte Empfangsstabilität und Spitzenqualität bei Anwendung eines Standard-Flansch‑UNI/DRO LNB der Marke Invacom SNF‑031, Baujahr 2006, zu benennen und zu analysieren. Dies bestätigt, dass selbst mit Standard-Komponenten der Signalkette und ohne Anwendung meiner technologischen Erfindung „Synchronous Nanocorrections“ in Mitteleuropa, bei der aktuellen EIRP-Intensität, eine Empfangsstabilität von über 99 % am Ausgang des PF 370 cm Reflektors von der analysierten Frequenz f = 11,430 MHz_H erreicht werden kann.
Heute, am 12.11.2025 um 11:00 CET, ist die Belegung des Transportstreams identisch mit dem Stand vom 09.11.2025, als ich gemessene Daten aus dem Frequenzspektrum mit dem neuen Referenzanalysator Televes Mosaiq‑6 mit 4K‑UHD Option bei dxsatcs.com erhoben habe. Das bedeutet, dass die heute veröffentlichten Daten zum Zustand des Transportstreams oder PAT‑Netzes auf f = 11,430 MHz_H die aktuellsten überhaupt sind.
Signal-Monitoring Analyse der Frequenz f = 11,430 MHz_H am Ausgang von PF 370 cm:
Zwischen dem 08.11. und 09.11.2025 führte ich in einer nicht-evidenziellen Einheit t = 25 Stunden 33 Minuten ein kontinuierliches Signal-Monitoring der Frequenz 11,430 MHz_H am Ausgang eines Prodelin-Reflektors mit D = 370 cm im Empfangsort Lučenec durch, unter insgesamt deutlich verschlechterten meteorologischen Bedingungen mit regelmäßigen Regenschauern, wie durch die Niederschlagssummen-Diagramme der Quelle shmu.sk / Boľkovce nachgewiesen.
Aus der Gesamtdauer der Signal-Monitoring-Einheit t = 1533 Minuten (25 h 33 min) erreichte ich eine vollständig stabile 100 %-ige Empfangsqualität ohne jegliche Pixelation im Bild oder Stream-Freeze über genau 1524 Minuten, was in Prozent 99,41 % Stabilität am Ausgang von PF 370 cm entspricht – selbst bei fast ganztägigem Regen vom 08. bis 09.11.2025.Ein regelmäßiges Auftreten der Qualitäts-Spitze um SNR = 9,4 dB zeichne ich täglich von 13:00 bis 20:00 Uhr auf, was zeigt, dass meine Aussagen über die Anwendbarkeit von Reflektoren ab D = 300 cm für potenziell instabilen Carrier-Lock von mehreren Stunden täglich auf f = 11,430 MHz_H in Mitteleuropa rational begründet sind. Die Qualitätsspitze bei SNR = 9,4 dB bedeutet, dass meine Signalkette mit D = 370 cm eine Signalmarge von bis zu 4,2 dB erzeugt, was Raum für Experimente in Richtung instabiler Lock-Bedingungen bereits am Ausgang von PF 300 cm bietet. Zwischen 08. und 09.11.2025 um Mitternacht registrierte ich nach Eintreffen von starken Regenwolken einen totalen Ausfall der Lock-Kontinuität für genau 9 Minuten – zugleich war dies der einzige kontinuierlich dokumentierte Lock-Ausfall über die gesamte Monitoring-Länge von 1533 Minuten auf diesem Träger, dessen Auftreten in direktem ursächlichen Zusammenhang mit den Regenfällen am Empfangsort steht, wie die Niederschlagssummen-Diagramme der Quelle shmu.sk / Station Boľkovce unwiderlegbar beweisen.
Transportstream-Belegung auf f = 11,430 MHz_H:
Der Betreiber Rascom ergänzte den Transportstream kurz vor dem letzten Wochenende auf der Trägerfrequenz f = 11,430 MHz_H um TV Canal 2 International in voller HD-Auflösung 1920×1080 und den Nachrichtensender France 24 (Fr) in SD-Auflösung 720×576, sodass der TS derzeit zwei TV-Übertragungen in voller HDTV-Auflösung, eine in SD-Auflösung und eine Radioübertragung Radio Kalangou enthält. Stand: 12.11.2025, 11:00 Uhr CET.
>Inštalovaný anténny reflektor Prodelin 370 cm slúžiaci na príjem z f=11 430 MHz_H
>Vyžarovací diagram North Africa družice Rascom QAF-1R na 2,9°E v ktorom je analyzovaná "C" vysielaná
SK_Signálny monitoring f=11 430 MHz_H na výstupe z reflektora Prodelin 370 cm v jednotke t=25 hodín
EN_Signal monitoring of the frequency f = 11,430 MHz_H at the output of a Prodelin 370 cm reflector over a period of t = 25 hours in the city of Lučenec, Slovakia.
DE_Signalüberwachung der Frequenz f = 11,430 MHz_H am Ausgang eines Prodelin-Reflektors mit 370 cm über eine Dauer von t = 25 Stunden in der Stadt Lučenec, Slowakei.
SK_poveternostné podmienky počas signálneho monitoringu zo zdroja shmu.sk,prevládala zamračená obloha a dažďové prehánky
EN_Weather conditions during the signal monitoring according to the source shmu.sk: predominantly overcast sky with rain showers.
DE_Wetterbedingungen während des Signal-Monitorings gemäß der Quelle shmu.sk: überwiegend bewölkter Himmel mit Regenschauern.
SK_Televes Mosaiq-6_11 430 MHz_H : analýza frekvenčného spektra,kvality,transportného streamu TS zaznamenaná dnes 12.11.2025.Tu je dôkaz že satelitná signálna distribúcia cez nosnú frekvenciu 10 870 MHz-H už bola ukončená
EN_New reference analyzer Televes Mosaiq‑6_11,430 MHz_H: analysis of the frequency spectrum, signal quality, and transport stream (TS) recorded today, 12.11.2025.EN_Here is the evidence that satellite signal distribution via the carrier frequency 10,870 MHz_H has already been terminated.
DE_Neuer Referenz-Analysator Televes Mosaiq‑6_11,430 MHz_H: Analyse des Frequenzspektrums, der Signalqualität und des Transportstreams (TS), aufgezeichnet am heutigen Tag, 12.11.2025.DE_Hier ist der Nachweis, dass die Satellitensignalverteilung über die Trägerfrequenz 10,870 MHz_H bereits beendet wurde.